compressor

4 Main Facilities :

  1. Suction Scrubber (V-850)
  2. Compressor  (C-855)
  3. After Cooler (E-860)
  4. Discharge Scrubber (V-865)

 

 SOP START UP :

    1. Check Inlet & Outlet Gas Compressor
    2. Check Electricity Power Supply
    3. Check Air Supply
    4. Reset Shutdown Signal
  1. Check Water Cooling System
  2. Check Lubrication Oil System
  3. Check Lubrication Draining System
  4. Check Venting
  5. Check safety relief valve (Open)
  6. SDV Close
  7. BDV Close ( Outlet Valve of BDV Open)
  8. Check Control Valve upstream & downstream (open). Bypass Close
  9. Power On water pump, cooling fan, prelubrication pump. Select Auto
  10. Power On 2 fan after cooler & compressor motor on MCC, select Auto
  11. Panelview :
      1. Click Ok & Click Shutdown Reset

     

    panelcomp1

     

      1. Check Set Point

     

    panelcomp2

     

    panelcomp2

     

    panelcomp2

     

    panelcomp2

     

    panelcomp2

     

      1. Press Return Main menu & Click First Out Shutdown

     

    panelcomp2

     

    1. Click Pilot light control
    2. Return to main menu, check SDV & BDV. Open inlet & outlet valve of compressor skid. Click " Checking Completed " button
    3. Purging if needed
    4. Check FY 851 Full Open, then click " Yes manul valve opened ". Ready, click "START"
    5. Check Alarm, FY 851 choose " Auto " or " Manual " load

 